Intraclass Correlation Coefficients
Includes: ICC(1,1), ICC(1,k), ICC(2,1), ICC(2,k), ICC(3,1), ICC(3,k) with confidence intervals; optional Repeatability Coefficient and SEM.
Purpose: Quantify reliability/agreement of measurements across raters/replicates using the standard Shrout–Fleiss ICC family.
Overview
The intraclass correlation coefficient (ICC) measures how strongly measurements of the same targets/subjects resemble each other relative to the total variability. ICC is commonly used for:
- inter-rater reliability (multiple judges rating the same targets)
- test–retest reliability (repeated measurements)
- agreement across measurement methods (when values are in the same units)
This add-in follows the Shrout & Fleiss (1979) naming convention:
- ICC(1,·): one-way random effects (raters/replicates treated as exchangeable)
- ICC(2,·): two-way random effects, absolute agreement
- ICC(3,·): two-way mixed effects (raters fixed), consistency
The second index denotes:
- (·,1): single measurement / single rater
- (·,k): mean of k measurements/raters (average-measures ICC)
Note: In the add-in, for ICC(2,k) and ICC(3,k), k is the number of columns (raters) in your selected data range.
Example dataset
Download the example dataset used here: 103intraclasscorrelation.csv
This dataset is from Shrout & Fleiss (1979). Use the judges columns as the input data range (e.g., judge1–judge4).
Screenshots
Input screen

Options

Results

When to use it
Use ICC when:
- multiple raters/replicates measure the same targets, and you want a single reliability index
-
you need either:
-
absolute agreement (raters should give the same numerical values), or
- consistency (raters can differ by a constant shift but preserve ranking)
Choose the ICC family based on your design and inference goal:
- ICC(1,·) (one-way random): raters/replicates are exchangeable; you do not model systematic rater effects.
- ICC(2,·) (two-way random, agreement): targets and raters are both random; you want to generalize to other raters and require agreement.
- ICC(3,·) (two-way mixed, consistency): raters are fixed (only these raters matter); you care about consistency rather than absolute agreement.
Inputs in Excel
Data
Select a rectangular numeric range where:
- rows = targets/subjects
- columns = raters/judges/replicates
Missing values
- ICC(1,1) and ICC(1,k): missing values are allowed (unbalanced targets) — the add-in uses an effective group size \(n_0\) (see below).
- ICC(2,·) and ICC(3,·): the design must be complete (no missing values), because these ICCs are based on a two-way ANOVA without replication.
Steps in the add-in
- Ribbon: BESH Stat NG → Analyse → Agreement → Intraclass Correlation Coefficients
- In Input, select the data range (raters in columns)
- Choose output destination (range / new worksheet / new workbook)
- In Options:
- Select ICC type (ICC(1,1), ICC(1,k), ICC(2,1), ICC(2,k), ICC(3,1), ICC(3,k))
- Set Alpha
- (Optional) check Repeatability Coefficient
- Click Compute
What it does (math and implementation details)
ANOVA mean squares used
All ICC types are computed using ANOVA mean squares.
Let:
- \(n\) = number of targets (rows)
- \(k\) = number of raters/replicates (columns)
For two-way designs (ICC(2,·), ICC(3,·)), the add-in uses a two-way ANOVA without replication (implemented via a repeated-measures one-way ANOVA table) to obtain:
- \(MSR\): mean square for rows (targets)
- \(MSC\): mean square for columns (raters)
- \(MSE\): residual mean square (interaction + error)
For one-way designs (ICC(1,·)), the add-in uses a one-way ANOVA on the per-target groups to obtain:
- \(MSB\): mean square between targets
- \(MSW\): mean square within targets (error)
ICC(1,1): one-way random effects, single measurement
Model (one-way random):
Point estimate (balanced case):
Unbalanced targets (missing values): the add-in uses an effective group size \(n_0\):
where \(g\) is the number of targets, \(n_i\) is the number of measurements for target \(i\), and \(n_{tot} = \sum_i n_i\).
Then:
Confidence interval (F-based)
Let \(F = MSB/MSW\) with \(df_1=g-1\), \(df_2=n_{tot}-g\) (the within df used by ANOVA).
Compute F bounds and transform back:
Then:
Balanced vs unbalanced designs (exactness of the CI)
The F-based confidence interval above is exact under the classical balanced one-way random-effects design (all targets have the same number of ratings, \(n_i=k\), and errors are normal).
If the design is unbalanced (missing values / unequal \(n_i\)), the add-in uses the effective group size \(n_0\) in the F-to-ICC transformation. In that case, the resulting CI should be regarded as an approximation, although it is commonly used in practice for one-way ICC with unequal group sizes.
ICC(1,k): one-way random effects, average of k measurements
Point estimate:
The add-in obtains the CI by transforming the ICC(1,1) limits \(L_1,U_1\) to the average-measures scale using \(n_0\):
Note (unbalanced designs): In balanced data \(n_0 \approx k\) and the ICC(1,k) CI is exact under the standard model assumptions. With missing values / unequal \(n_i\), the transformation uses \(n_0\), so the ICC(1,k) CI is an approximation.
ICC(2,1): two-way random effects, absolute agreement, single measurement
Point estimate:
Confidence interval (F-based transformation)
Let:
Then:
Compute \(F_L,F_U\) using \(df_R=n-1\), \(df_E=(n-1)(k-1)\):
Transform:
ICC(2,k): two-way random effects, absolute agreement, average of k raters
Point estimate:
Write in terms of:
Then:
CI is computed by placing bounds on \(F\) (same \(df_R,df_E\) as above) and transforming:
ICC(3,1): two-way mixed effects, consistency, single measurement
Point estimate:
CI is obtained by transforming F bounds with \(F = MSR/MSE\):
ICC(3,k): two-way mixed effects, consistency, average of k raters
Point estimate:
Thus the CI is obtained by transforming \(F_L,F_U\) directly:
Repeatability Coefficient (optional)
If Repeatability Coefficient is selected, the add-in also reports:
- SEM (standard error of measurement) in the original measurement units
- Repeatability Coefficient (RC), interpreted as a 95% repeatability limit for the absolute difference between two measurements on the same target under repeatability conditions.
Let \(z_{1-\alpha/2}\) be the standard normal quantile (for \(\alpha=0.05\), \(z_{0.975}\approx 1.96\)).
The add-in first computes a measurement-error variance (call it \(V\)) that is consistent with the currently selected ICC type, then:
Variance \(V\) used (matches the selected ICC)
Let:
- \(n\) = number of targets (rows)
- \(k\) = number of raters/replicates (columns)
- \(MSW\) = one-way within-target mean square
- \(MSC\) = two-way columns (rater) mean square
- \(MSE\) = two-way residual mean square
ICC(1,1) (one-way, single):
ICC(1,k) (one-way, average-measures):
For unbalanced data, the add-in uses the effective group size \(n_0\) (same \(n_0\) as used in the ICC(1,·) CI transform):
Note: in balanced data \(n_0 \approx k\), so this reduces to \(MSW/k\).
ICC(2,1) (two-way random, absolute agreement, single):
This ICC includes the effect of rater-to-rater variability in what counts as measurement error for agreement. The add-in uses:
ICC(2,k) (two-way random, agreement, average-measures):
ICC(3,1) (two-way mixed, consistency, single):
For consistency ICC, systematic rater differences are not treated as “error” for the ICC, so the add-in uses:
ICC(3,k) (two-way mixed, consistency, average-measures):
Confidence interval for RC
The add-in forms a chi-square CI for the variance \(V\), then transforms to RC.
- For ICC(1,·) (one-way): \(V\) is based on \(MSW\) with the one-way within df \(df_W\).
- For ICC(2,·) (two-way random agreement): when \(MSC > MSE\), \(V\) is a linear combination of \(MSE\) and \(MSC\), and an approximate Satterthwaite df is used:
If \(MSC \le MSE\), the add-in sets \(\sigma_R^2=0\) so \(V=MSE\) and uses \(df_E\).
- For ICC(3,·) (two-way mixed consistency): \(V\) is based on \(MSE\) with df \(df_E\).
Given an effective df (call it \(df_V\)), the variance CI is:
Then:
How to interpret (quick guide)
ICC magnitude (rules of thumb)
Interpretation depends on context, but commonly used thresholds (Koo & Li, 2016) are:
- < 0.50: poor
- 0.50–0.75: moderate
- 0.75–0.90: good
-
0.90: excellent
What each ICC answers
| ICC type | Model | Agreement type | Generalizes to other raters? | Use when… |
|---|---|---|---|---|
| ICC(1,1) | one-way random | agreement | yes (exchangeable) | raters/replicates are exchangeable; no explicit rater effect |
| ICC(1,k) | one-way random | agreement | yes (exchangeable) | reliability of the mean of k measurements |
| ICC(2,1) | two-way random | absolute | yes | want agreement and generalize to other raters |
| ICC(2,k) | two-way random | absolute | yes | agreement for the mean of k raters |
| ICC(3,1) | two-way mixed | consistency | no (fixed raters) | only these raters matter; shifts are acceptable |
| ICC(3,k) | two-way mixed | consistency | no (fixed raters) | consistency for the mean of k fixed raters |
Relationship to R (how to reproduce)
Using the irr package
library(irr)
d <- read.csv("103intraclasscorrelation.csv")
X <- as.matrix(d[, -1]) # drop target column
# ICC(1,1): one-way random, single
icc(X, model = "oneway", type = "consistency", unit = "single")
# ICC(1,k): one-way random, average of k
icc(X, model = "oneway", type = "consistency", unit = "average")
# ICC(2,1): two-way random, absolute agreement, single
icc(X, model = "twoway", type = "agreement", unit = "single")
# ICC(2,k): two-way random, absolute agreement, average
icc(X, model = "twoway", type = "agreement", unit = "average")
# ICC(3,1): two-way mixed, consistency, single
icc(X, model = "twoway", type = "consistency", unit = "single")
# ICC(3,k): two-way mixed, consistency, average
icc(X, model = "twoway", type = "consistency", unit = "average")
Most ICC packages (e.g., irr, psych) compute ICCs and CIs, but do not directly report the same Repeatability Coefficient/SEM definitions.
Expected differences
- ICC values and ICC confidence intervals may differ slightly across R packages because of differences in CI construction (exact vs approximate, df conventions, and handling of missing data).
- For ICC(1,·) with missing values/unbalanced targets, some software uses the nominal \(k\), while this add-in uses the effective group size \(n_0\) in the ICC(1,k) transformation and RC/SEM scaling.
- RC/SEM are not standardized across software: some tools report SEM as \(SD\sqrt{1-ICC}\) (a different definition), while the add-in’s RC/SEM are ANOVA-variance based and aligned to the selected ICC model (agreement vs consistency).
Notes and limitations
- ICC confidence intervals are based on ANOVA assumptions (approximately normal errors and appropriate variance decomposition). CIs can be asymmetric and may include negative values.
- ICC(2,·) and ICC(3,·) require complete data (no missing cells).
- “High ICC” does not automatically mean “small measurement differences”; consider also reporting the Repeatability Coefficient when measurement units matter.
References
- Shrout, P. E., & Fleiss, J. L. (1979). Intraclass correlations: uses in assessing rater reliability. Psychological Bulletin, 86(2), 420–428.
- McGraw, K. O., & Wong, S. P. (1996). Forming inferences about some intraclass correlation coefficients. Psychological Methods, 1(1), 30–46.
- Koo, T. K., & Li, M. Y. (2016). A guideline of selecting and reporting intraclass correlation coefficients for reliability research. Journal of Chiropractic Medicine, 15(2), 155–163.