ROC Curve
Includes: ROC curve points, AUC (Wilcoxon), DeLong SE / CI, Hanley–McNeil SE / CI, p-value, Cutoff table. Purpose: Assess binary classifier performance and explore sensitivity/specificity tradeoffs across thresholds.
Overview
A Receiver Operating Characteristic (ROC) curve summarizes the performance of a binary classifier across all possible decision thresholds.
In BESHStatNG, you provide one continuous marker measured in:
- Characteristic present (patients / positives)
- Characteristic absent (controls / negatives)
BESHStatNG then:
- Builds a list of cut-offs (thresholds) between unique marker values,
- Computes Sensitivity and Specificity for each cut-off,
- Plots Sensitivity versus 1 − Specificity (false positive rate),
- Computes AUC (area under the ROC curve) using the Wilcoxon/Mann–Whitney definition,
- Reports two standard errors / confidence intervals for AUC:
- DeLong (recommended for the SE of a single AUC; also widely used for ROC comparisons)
- Hanley–McNeil (classic approximation; often reported and used in older literature)
- Reports a two-sided p-value for \(H_0:\,\text{AUC}=0.5\) using the method implemented in
ROC.vb.
Example dataset
The screenshots use this example dataset (two columns: disease present vs disease absent):
Screenshots
Input tab

Options tab

Results (summary tables + ROC chart)

When to use it
Use ROC analysis when:
- You have a binary outcome (disease present/absent, case/control, responder/non-responder),
- You have one continuous marker or score you want to evaluate,
- Higher marker values indicate “more likely positive” (see Notes if your direction is reversed).
Typical use cases:
- Diagnostic biomarkers
- Risk scores
- Classifier output scores (probabilities, logits, etc.)
Inputs in Excel
Group by Column (two input ranges)
Use this when you have two separate columns:
-
Group with characteristic present (patients)
Example:'008roc'!$A:$A -
Group with characteristic absent (controls)
Example:'008roc'!$B:$B
Only numeric values are used; blank cells are ignored by the data import layer.
Group by ID (one data column + one group column)
Use this when your data are in one marker column and one group ID column (with exactly two unique IDs).
- Group ID: a column identifying the two groups
- Data: the marker column
BESHStatNG expects exactly two unique group IDs for ROC.
Output destination
- Output Range (current sheet)
- New Worksheet
- New Workbook
Options
Full Descriptive Statistics
If checked, BESHStatNG appends a descriptive statistics table for each group (see also: Descriptive Statistics).
Steps in the add-in
- Ribbon: BESH Stat NG → Analyse → Graphics → ROC Curve
- In Input:
- Choose Group by Column or Group by ID
- Select the required ranges
- In Options:
- Optionally enable Full Descriptive Statistics
- Choose output destination
- Click Compute
What it does (math and implementation details)
A) Classification rule at a cut-off
For a cut-off \(c\), BESHStatNG uses the rule:
- predict positive (patient) if marker \( \ge c \)
- predict negative (control) if marker \( < c \)
Let:
- \(n_1\) = number of patients (positives)
- \(n_2\) = number of controls (negatives)
At cut-off \(c\):
- \(TP\) = # patients with marker \( \ge c \)
- \(FN\) = # patients with marker \( < c \)
- \(TN\) = # controls with marker \( < c \)
- \(FP\) = # controls with marker \( \ge c \)
Then:
The ROC curve is plotted with:
B) How cut-offs are chosen (as implemented)
BESHStatNG collects all distinct marker values across both groups and sorts them:
Cut-offs are defined as midpoints between adjacent unique values:
and the last cut-off is set above the maximum:
This ensures all observations fall on one side of at least one cut-off.
C) AUC (Wilcoxon / Mann–Whitney)
BESHStatNG reports Wilcoxon AUC, which is equivalent to the Mann–Whitney \(U\) statistic:
Interpretation:
- \(\text{AUC}=0.5\): no discrimination (random)
- \(\text{AUC}=1\): perfect separation
- \(\text{AUC}<0.5\): “wrong direction” (controls tend to have higher values than patients)
D) DeLong standard error and confidence interval
BESHStatNG computes the DeLong standard error using a nonparametric U-statistic approach (tie-safe via midranks).
Define the kernel:
For each patient \(i\) and control \(j\), define “influence” (placement) values:
Then:
DeLong’s variance estimate for independent groups is:
and the standard error is:
DeLong CI in BESHStatNG is the normal CI using this SE:
E) Hanley–McNeil standard error and confidence interval
BESHStatNG also reports a Hanley–McNeil–style variance form:
and reports:
A \((1-\alpha)\) CI is computed as:
\(Q_1\) and \(Q_2\) are computed internally (tie-aware) in ROC.vb.
E) p-value for \(H_0:\,\text{AUC}=0.5\)
BESHStatNG uses a normal approximation:
with a separate finite-sample standard error derived from the mathematical relationship between the Area Under the ROC Curve (AUC) and the Wilcoxon-Mann-Whitney U statistic:
Two-sided p-value:
where \(\Phi\) is the standard normal CDF.
Note: this p-value is not computed using DeLong or Hanley–McNeil SE in the current implementation.
G) Which SE/CI should you use?
For a single AUC, DeLong is generally the preferred method for standard error estimation because it is a nonparametric U-statistic approach and is widely recommended in ROC analysis workflows.
Hanley–McNeil is a classic approximation and is still seen in older ROC literature; it is often used (historically) for inference and is commonly referenced when comparing independent ROC curves.
In BESHStatNG both are reported so you can compare sensitivity of inference to the SE choice.
Outputs written to Excel
1) Summary table
BESHStatNG writes a small summary block:
- Wilcoxon AUC
- DeLong confidence interval at the selected \(1-\alpha\) level
- DeLong Standard error
- Hanley–McNeil confidence interval at the selected \(1-\alpha\) level
- Hanley–McNeil Standard error
- Two-sided p-value (AUC different from 0.5)
2) Cut-off table
A table with columns:
- Cut-Off
- Sensitivity
- Specificity
This table is useful for picking a threshold (e.g., maximize Youden’s \(J = \text{Sensitivity} + \text{Specificity} - 1\)).
3) ROC plot
A scatter-line ROC plot is created on the same output sheet:
- \(y\): Sensitivity
- \(x\): \(1-\)Specificity
- plus a diagonal reference line.
4) Optional descriptive statistics
If Full Descriptive Statistics is checked, BESHStatNG appends descriptive stats by group.
How to interpret (quick guide)
- AUC is a single-number summary of discrimination:
- 0.7–0.8: acceptable (context-dependent)
- 0.8–0.9: good
-
0.9: excellent
- The ROC curve closer to the top-left indicates better performance.
- Choose a cut-off based on your goal:
- maximize sensitivity (screening),
- maximize specificity (confirmatory testing),
- or balance via Youden’s \(J\).
Relationship to R (how to reproduce)
The add-in uses specific formulas for SE, p-value, and CI. To reproduce the same numbers as BESHStatNG (including p-value), use the reference code below.
R code (matches ROC.vb, including DeLong SE/CI)
# Reference ROC implementation matching BESHStatNG (ROC.vb)
#
# - Cut-offs: midpoints between sorted unique values, last = max + 1
# - Sensitivity: P(marker >= cutoff | patient)
# - Specificity: P(marker < cutoff | control)
# - AUC: Wilcoxon / Mann–Whitney with 0.5 credit for ties
# - SE_HM / CI_HM: Hanley–McNeil style variance as implemented in ROC.vb
# - SE_DeLong / CI_DeLong: DeLong SE with midranks, CI = AUC ± z * SE_DeLong
# - p-value: uses ROC.vb's SE_p formula (not SE_HM nor SE_DeLong)
midranks <- function(x) {
o <- order(x)
r <- numeric(length(x))
i <- 1L
while (i <= length(x)) {
j <- i
while (j < length(x) && x[o[j + 1]] == x[o[i]]) j <- j + 1L
r[o[i:j]] <- (i + j) / 2
i <- j + 1L
}
r
}
delong_se <- function(patients, controls) {
m <- length(patients); n <- length(controls)
scores <- c(patients, controls)
r_all <- midranks(scores)
# Within-group midranks (original order)
r_x <- midranks(patients)
r_y <- midranks(controls)
# Combined ranks in original order
r_x_all <- r_all[1:m]
r_y_all <- r_all[(m + 1):(m + n)]
# AUC from ranks (same Wilcoxon AUC)
U <- sum(r_x_all) - m * (m + 1) / 2
auc <- U / (m * n)
v <- (r_x_all - r_x) / n
w <- (r_y_all - r_y) / m
var_auc <- var(v) / m + var(w) / n
se <- sqrt(var_auc)
list(auc = auc, var = var_auc, se = se)
}
roc_besh <- function(patients, controls, alpha = 0.05) {
n1 <- length(patients)
n2 <- length(controls)
n <- n1 + n2
data12 <- c(patients, controls)
arIDs <- c(rep(1L, n1), rep(2L, n2)) # 1=patients, 2=controls
o <- order(data12)
data12 <- data12[o]
arIDs <- arIDs[o]
arUnique <- sort(unique(data12))
m <- length(arUnique)
# Cutoffs (m values)
cutoffs <- numeric(m)
if (m >= 2) cutoffs[1:(m - 1)] <- (arUnique[1:(m - 1)] + arUnique[2:m]) / 2
cutoffs[m] <- arUnique[m] + 1
# Arrays (match ROC.vb)
sensitivity <- numeric(m + 1) # includes endpoints for plotting
fpr <- numeric(m + 1) # 1 - specificity, includes endpoints
specificity <- numeric(m)
patientsGroup <- numeric(m)
controlsGroup <- numeric(m)
patientsCum <- numeric(m)
controlsCum <- numeric(m)
# a,b,c,d counters (see ROC.vb)
c_cnt <- 0L
d_cnt <- 0L
j <- 1L
patientsCum[1] <- n1
# AUC + Hanley–McNeil SE intermediates
auc_sum <- 0
q1_sum <- 0
q2_sum <- 0
for (i in 1:m) {
while (j <= n && data12[j] < cutoffs[i]) {
if (arIDs[j] == 1L) {
c_cnt <- c_cnt + 1L
patientsGroup[i] <- patientsGroup[i] + 1
} else {
d_cnt <- d_cnt + 1L
controlsGroup[i] <- controlsGroup[i] + 1
}
j <- j + 1L
}
a <- n1 - c_cnt
b <- n2 - d_cnt
# ROC points
sensitivity[i + 1] <- a / (a + c_cnt)
specificity[i] <- d_cnt / (b + d_cnt)
fpr[i + 1] <- 1 - specificity[i]
# Wilcoxon AUC and SE components
if (i == 1) {
patientsCum[i] <- patientsCum[i] - patientsGroup[i]
} else {
patientsCum[i] <- patientsCum[i - 1] - patientsGroup[i]
controlsCum[i] <- controlsCum[i - 1] + controlsGroup[i - 1]
}
auc_sum <- auc_sum + (controlsGroup[i] * patientsCum[i] +
0.5 * controlsGroup[i] * patientsGroup[i])
q2_sum <- q2_sum + (patientsGroup[i] *
(controlsCum[i]^2 +
controlsCum[i] * controlsGroup[i] +
(1/3) * controlsGroup[i]^2))
q1_sum <- q1_sum + (controlsGroup[i] *
(patientsCum[i]^2 +
patientsCum[i] * patientsGroup[i] +
(1/3) * patientsGroup[i]^2))
}
# Endpoints for plotting (exactly as ROC.vb)
sensitivity[1] <- 1
fpr[1] <- 1
sensitivity[m + 1] <- 0
fpr[m + 1] <- 0
auc <- auc_sum / (n1 * n2)
# Hanley–McNeil SE (as implemented)
q2 <- q2_sum / (n1 * (n2^2))
q1 <- q1_sum / (n2 * (n1^2))
se_hm <- sqrt((auc * (1 - auc) +
(n1 - 1) * (q1 - auc^2) +
(n2 - 1) * (q2 - auc^2)) / (n1 * n2))
z <- qnorm(1 - alpha / 2)
ci_hm <- c(lower = auc - z * se_hm, upper = auc + z * se_hm)
# DeLong SE/CI (as implemented)
del <- delong_se(patients, controls)
se_delong <- del$se
ci_delong <- c(lower = auc - z * se_delong, upper = auc + z * se_delong)
# p-value uses ROC.vb's special SE_p
se_p <- sqrt((0.25 + (n1 + n2 - 2) * 0.083333) / (n1 * n2))
p_value <- 2 * pnorm(-abs(auc - 0.5) / se_p)
list(
auc = auc,
se_delong = se_delong,
ci_delong = ci_delong,
se_hm = se_hm,
ci_hm = ci_hm,
p_value = p_value,
cutoff_table = data.frame(
CutOff = cutoffs,
Sensitivity = sensitivity[1:m], # matches wrapResults() indexing
Specificity = specificity
),
# Plotting arrays (include endpoints):
sensitivity_plot = sensitivity,
fpr_plot = fpr
)
}
# --- Reproduce the example from 008roc.csv ---
dat <- read.csv("008roc.csv")
patients <- dat[[1]]
controls <- dat[[2]]
# drop NAs (in case columns are uneven)
patients <- patients[!is.na(patients)]
controls <- controls[!is.na(controls)]
res <- roc_besh(patients, controls)
res
# Plot (reverse order so it draws from (0,0) to (1,1))
plot(rev(res$fpr_plot), rev(res$sensitivity_plot),
type = "b",
xlab = "1 - Specificity",
ylab = "Sensitivity",
main = "ROC curve (BESHStatNG-compatible)")
abline(a = 0, b = 1)
Quick cross-check with pROC (DeLong CI)
If you want a package implementation of DeLong CI:
# install.packages("pROC")
library(pROC)
dat <- read.csv("008roc.csv")
patients <- dat[[1]][!is.na(dat[[1]])]
controls <- dat[[2]][!is.na(dat[[2]])]
marker <- c(patients, controls)
group <- c(rep(1, length(patients)), rep(0, length(controls))) # 1=patient, 0=control
roc_obj <- roc(response = group, predictor = marker, direction = ">")
auc(roc_obj)
ci.auc(roc_obj, method = "delong")
Note: pROC’s DeLong CI is typically based on DeLong variance; small numerical differences can occur due to implementation choices and tie handling.
Notes and limitations
- Direction matters: the implementation assumes higher marker values indicate “more likely patient/positive”. If your marker is reversed, you can swap the groups or use \(-\text{marker}\).
- p-value and CIs use normal approximations; in small samples, exact/permutation methods may differ.
- CIs are not forced into \([0,1]\) (they are straight normal CIs).
- ROC is implemented for two groups and one marker at a time.